5-6. CABINET REPLACEMENT (Con't).
(13) Remove two nuts (6) and straight adapters (6) from rear wall of cabinet (7). Remove
grommets (10) and discard.
(14) Use location of clips for precheck tubing in removed cabinet (7) as a guide to mark location of
b. CLEANING
(1)
Remove all traces of old mylar tape from mounting surfaces of cabinet and braces to frame.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear protective
goggles, face shield, and gloves, and use only in a well-ventilated area.
Avoid contact with skin, eyes, and clothes and DO NOT breathe vapors. DO
NOT use near open flame or excessive heat. The solvent's flash point is
100oF-138F (38C-59C). If you become dizzy while using cleaning
solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes with water and get medical aid.
(2)
Use dry cleaning solvent to clean mounting surfaces of cabinet and braces to frame. Dry
thoroughly.
c. INSTALLATION
CAUTION
To protect against corrosion and distortion of components, mylar tape must
be applied to mounting surfaces of cabinet (7) and brace (20) to frame.
(1)
Apply suitable width of mylar tape to mounting surfaces of cabinet (7) and brace (20) to
frame. Pierce holes in mylar tape at mounting bolt holes to prevent water accumulation.
5-19