TM 9-2330-398-10
2-19.
BASIC BULK HAUL AND FUEL-SERVICING OPERATIONS NOT INVOLVING USE OF ENGINE AND PUMP
(continued).
5.
Remove dust cover (19) from outlet B (17). Connect 4-inch (10.16-cm) bulk delivery hose to outlet B (17) and
storage facility.
6.
Remove fire extinguishers (6) and bring to point of operation.
7.
Make sure valve E (13) is in UNLOAD position.
8.
Pull emergency valve A control handle (10) to OPEN position and open valves B, G, and H (18, 20, and 21) to
begin flow.
9.
At end of operation, close all valves. Drain 4-inch (10.16-cm) bulk delivery hose into suitable container.
Disconnect hose and put it in hose trough. Secure hose trough latches. Install dust cover (19) on outlet B (17).
10.
WARNING
DO NOT let go of static reel grounding cable when rewinding until ball stop is firmly touching reel.
Failure to follow this warning may cause injury to personnel.
11.
Remove static reel grounding cable (15) from ground rod (16) or suitable ground.
12.
Store and cover fire extinguishers (6).