TM 9-2330-398-10
2-20. NONFILTERED FUEL SERVICING INVOLVING USE OF ENGINE AND PUMP.
a. SELF-LOAD
NOTE
Use this procedure when it is necessary to use onboard engine and pump to load fuel from
storage facility to semi-trailer.
Operation begins and ends with all valves closed.
1.
2.
Make sure all valves are closed.
3.
Connect static reel grounding cable (4) to
storage facility. Remove fire extinguishers and
bring to point of operation.
4.
warm, adjust to idle speed (1000-1200 rpm).
5.
Disconnect spring pins and turn hose trough
bars out of the way to remove 4-inch (10.16-cm)
bulk fuel hose from hose trough.
6.
Remove dust cover (5) from outlet B (6) and
connect bulk fuel hose to outlet B (6) and
storage facility.
7.
Put valve E (2) in LOAD position.
8.
Pull emergency valve A control handle (1) to
OPEN position.
9.
Open valves B and G (7 and 8).
10.
Adjust engine throttle for desired flow rate (refer
Table 2-3. Fuel-Dispensing Flow Rates in Gallons per Minute (GPM)
DISPENSING
BULK DELIVERY
SELF-LOAD
FILTERED
NONFILTERED
FILTERED
NONFILTERED
ENGINE RPM
2200
2400
1200
2400
2200
2400
2200
2400
PUMP GPM
290
320
44
88
44
88
175
190
480
530
2-52