TM 9-2590-506-13&P
5-8.
GENERAL. This section provides maintenance
a. Clean all parts with a wiping rag (item 5,
instructions for direct support personnel.
The
instructions cover removal, repair, installation and
checkout of components of the converter assembly.
WARNING
5-9.
CLEANING.
Clean the converter assembly
parts and/or components as follows:
Compressed air used for cleaning
purposes will not exceed 20 psi. Use
WARNING
only with effective chip guarding and
personnel
protection
equipment
Dry cleaning solvent is toxic and
(goggles/shield, gloves, etc.).
flammable. Avoid prolonged contact
with skin and keep away from open
b. Using compressed air with maximum nozzle
flame. Use only in well-ventilated
pressure of 20 psi, or a clean dry wiping rag
area.
5-10. ELECTRICAL RECEPTACLE MAINTENANCE INSTRUCTIONS
This task covers:
a. Removal
d. Installation
b. Cleaning
e. Checkout
c. Repair
INITIAL SETUP
Tools, Special Tools and Test Equipment
Personnel Required
Socket, Socket Wrench, 1/2-inch Drive,
One
9/16-inch
Socket Handscrew Key, 1/4-inch
Condition Description
Socket Handscrew Key, 3/16-inch
None
Fixed Open End Wrench, 9/16-inch
Special Environmental Conditions
Socket , Socket Wrench, 1/2-inch Drive,
3/16-inch
None
Flat Tip Screwdriver, 1/4-inch tip, 4-
inch long blade
Torque Wrench, 1/2-inch Drive, 150
pound-inches
Material/Parts
Gasket, Electrical Receptacle
Packing, Junction Box
5-8