LUBRICATION (CONT' )
D
CIRCULATORY PRESSURE LUBRICATION
Figure 1.
R-Reservoir. Check weekly. Use oil 450/600 S.S.U. viscosity at 100 F. Clean out twice a year.
O-Oil cups or grooves. Same oil as above.
G-Pressure fittings. Use soft grease of #2 consistency.
S--Sight oilers. To regulate loosen or tighten wick.
F-Filter.
*-See opposite side of machine.
Lubrication of the crossrail unit is accomplished by
into the machine before starting. After the machine is
metering pins. The oil flow to these pins is regulated by
started some of the oil will remain in the lines and it may
a bleeder hole in the line located inside the frame. In
be necessary to add oil.
the case of too little or too much oil being delivered to
the crossrail unit due to oil temperature or viscosity
Machine
Gallons
conditions, the bleeder plug should not be altered or
incorrect pressures may result. Gould and Eberhardt
16" Tool Room Shapers
5
should be consuited about furnishing the necessary plug
with correctly modified orifice.
16", 16-20", 20" and 20-24"
The following approximate amounts of lubricating
Industrial Shapers
7
oil
are
required
and
should
be
put
24", 28", 32" heavy
Industrial Shapers
11
2