39
Annually
Flywheel
a.
Flywheel is broken,
cracked, or damaged.
b.
Open both side doors and front door.
c.
Remove screws, flat washers, and shroud.
d.
Inspect flywheel for any damage such as
cracks, broken or missing air vanes, or broken
gear teeth. Notify direct support maintenance
to replace it if damaged.
e.
Install shroud, flat washers, and screws.