TM 9-4110-255-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model F5000RD - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable I f:
Item to
Check/
Service
29
Semi-
Engine Speed a.
Check for loose or missing mounting
Mounting hardware or
Annually
Switch
hardware and wire terminals.
Tighten or wire terminals are loose.
Case is damaged.
b.
Inspect case for cracks, breaks, or evidence of
overheating. Replace if damaged
30
Semi-
Control
a.
Check for loose or missing mounting
Mounting hardware or
Annually
hardware and wire terminals.
Tighten or wire terminals are loose.
Case is damaged.
b.
Inspect case for cracks, breaks, or evidence of
overheating.
Replace if damaged
31
Semi-
Continuous
a.
Check for loose or missing mounting
Mounting hardware or
Annually
hardware and wire terminals.
Tighten or wire terminals are loose.
Case is damaged.
b.
Inspect case for cracks, breaks, or evidence of
overheating. Replace if damaged
c.
Refrigeration
Unit Interior
32
Semi-
Defrost
a.
Inspect for frayed or broken wire leads. If
Wire lead frayed or
Annually
Termination
damaged, repair or replace as needed
broken. Thermostat loose
Thermostat
on tubing.
(Temperature
Switch)
b.
Check that the thermostat is in contact with
the tubing. Tighten if loose.
4-26