TM 9-4110-256-14
5-5.
FAN DRIVE SHAFT REPLACEMENT.
This task covers: a. Removal
b. Installation
INITIAL SETUP
General Safety Instructions:
Equipment Conditions:
WARNING
disconnected.
High voltage and exposed rotating
parts are used in the refrigeration unit.
Personal injury can result if power is
connected.
a. Removal. Remove fan drive shaft (1).
b. Installation. Install fan drive shaft (1).
Figure 5-4. Fan Drive Shaft
NOTE
FOLLOW-ON MAINTENANCE:
Connect power and put unit back into service.
5-6.
REFRIGERATION SYSTEM REPAIRS.
The refrigeration system must be totally discharged (para 5-8) before any maintenance is performed on system
components. Leak testing (para 5-11) and dehydrator replacement (para 5-15) are required after any system component
function correctly.
5-9