(5) Loosen set screw (9) and remove pulley (10) and key (11).
(6) If motor mount plate (12) must be replaced, remove self locking nut (13), flat washer (14), two cotter pins (15),
flat washers (16), motor mount hinge pin (17), motor mount plate, flat washer (18), and self locking nut (19).
Discard self locking nuts and cotter pins.
Figure 4-28. AC Motor
c. Installation.
(1) If motor mount plate (12) was removed, install new self locking nut (19), flat washer (18), motor mount plate,
motor mount hinge pin (17), two flat washers (16), new cotter pins (15), flat washer (14), and new self locking nut
(13).
(2) Install one new tab housing (20) and tab (21) onto each pair of new AC motor (4) wire leads T1/T7, T2/T8, and
(3) Install key (11) and pulley (10). Tighten set screw (9).
(4) Install AC motor (4), four new lock washers (8) and bolts (7).
(5) Install wire leads (3), connector (6), and connector locknut (5).
(6) Using tags and wiring diagram (fig. 1-4), connect wire leads (3).
4-75