TM 9-4110-258-13
4-32. PULLEY REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
General Safety Instructions:
WARNING
disconnected.
High voltage and exposed rotating parts are
used in the refrigeration unit. Personal injury
can result if power is connected.
a. Removal. Loosen set screw (1) and remove pulley (2) from AC motor (3) shaft being careful not to lose key (4).
b. Installation. Install key (4) then align pulley (2) with key and slide onto AC motor (3) shaft. Tighten set screw (1).
Figure 4-26. Pulley
NOTE
FOLLOW-ON MAINTENANCE:
Connect power and put unit back into service.
4-71