9-4120-370-14
TO 35 E9-229-1
4-9.
ALTERNATE INPUT POWER CABLE CONNECTOR (J1) LOCATIONS - Continued
(2) Using screwdriver, loosen five captive panel fastener screws.
(3) Tip top of lower front panel away from unit and lift panel up to clear flange on bottom of panel.
(4) Using screwdriver and wrench, remove four screws and nuts from J1 connector.
Remove J1 connector and harness, rubber gasket, and electrical cover cap and chain from mounting plate.
(5)
Using screwdriver and wrench, remove four screws and nuts from cover plate at alternate connector loca-
(6)
tion
(7)
Using screwdriver and wrench, install connector J1, electrical cover cap and chain, and rubber gasket in
new location with four screws and nuts.
Using screwdriver and wrench, install cover plate on mounting plate where J1 connector was removed with
(8)
four screws and nuts.
Reinstall lower front panel.
(9)