4-50. TIME DELAY RELAY (K6) - Continued.
(3) See tags and wiring diagram (Figure 4-20) and solder leads.
(4) Slip heat shrinkable tubing over exposed solder connections, bare terminals, and shrink in place.
Install junction box cover and lower front cover. (See para 4-46.)
Followon procedure:
4-51. TRANSFORMER (T)
Preliminary procedure:
Figure 4-70. Transformer (T)
Removal
a.
(1) Using a screwdriver, remove ten screws and lock washers from junction box cover.
(2) Remove cover.
(3) Tag and disconnect wire leads.
(4) Using wrench, remove four nuts and lock washers from transformer mounting studs.
Test
b.
(1) Connect the probes of a continuity tester or a Multimeter set on the lowest OHMS scale to terminal studs
H1 and H2. If the primary winding is open, replace the transformer.
(2) Connect the probes of a continuity tester or a Multimeter set on the lowest OHMS scale to terminal studs
X1 and X2. If the secondary winding is open, replace the transformer.
4-101