TM 9-4120-378-14
4.27 COMPRESSOR START RELAY - Continued
Remarks
Action
Location/ltem
a. Using tags as a guide, connect electrical leads
Installation
(4), (5), and (6) to the compressor start relay (K5)
(3) and remove tags.
Silicone Adhesive Sealant RTV, Type 1,
MI L-A-46106, releases acetic acid during
application and curing. Use in well-venti-
lated area to stay below 10 ppm acetic
acid. Avoid prolonged skin contact, pro-
longed inhalation of vapors, and eye
contact.
b. Coat the terminals and electric leads (1) with 1/8
inch of silicone adhesive sealant RTV (Item 1,
screw (1) and Iockwasher (2) through mounting
tab.
d. Install rear and center top covers.