TM 9-4120-378-14
Remarks
Action
Location/Item
c.
Remove four nuts (14) and four flat washers (15)
disassembly
securing inlet ring (16) to flange (17).
Continued
d.
Remove inlet ring (16).
e.
Withdraw impeller (18) and shaft extension (13)
through opening of flange (17).
Loosen setscrew (19) of impeller (18) that se-
f.
cures impeller to shaft extension (13).
Remove shaft extension (13) from impeller (18).
g.
h.
Remove four screws (20) and four nuts (21 ) se-
curing flanges (17 and 22) to base (23).
i.
Remove two screws (24) and flat washer (25) on
strap (26). Remove strap (26).
Remove flange (17).
j.
k.
Remove housing (27).
l.
Remove flange (22) with inlet ring (28).
m. Remove four nuts (29) and four flat washers (30)
securing inlet ring (28) to flange (22) and remove
inlet ring (28).
Inspect shaft extension (13), fan inlet rings (16
a.
Inspection
and 28), impeller (18), flanges (17 and 22),
straps (11 and 26) and housing (27) for visible
out-of-round conditions, dents, burrs and nicks.
Replace defective items.
b.
Check impeller (18) for damaged or bent vanes.
c.
Straighten or replace impeller (18).
4-81