5.24 CONDENSER COIL. - continued
Remarks
Location/Item
Action
Removal
d. Remove four screws (10) and two mounting
Continued
clamps (11) attaching receiver tank (12) to housing.
e. Purge system.
f. Reposition electrical wiring away from piping area See paragraph 5.6.
to be debrazed.
Use extreme care in removing con-
denser coil from housing to avoid
damaging fins and coil piping.
i.
Remove condenser coil from unit.
Debraze receiver tank (12) and liquid sight indica-
j.
Installation
a. Braze the receiver tank(12) and liquid sight indica-
5-72