TM 9-4120-385-14
a.
WARNING
High voltage can kill.
Tag and disconnect electrical leads from C1, K10, C2, E3, E4, and K7.
1.
2.
Refer to Chapter 5 for removal of leads to pressure switches.
3.
Refer to Chapter 5 for removal of solenoid valves L1 and L2.
4.
Disconnect P7, P10, P3, J1, P8, P4, and P2.
5.
Remove thermostat S2 using two screws.
6.
Remove all cable clamps and attaching hardware and harness.
Cut tie straps as required.
7.
b.
INSPECTION.
1.
Inspect for broken leads, missing terminals, and broken solder joints.
2.
Check for frayed or broken wires, loose connector pins and damage.
c.
TESTING. Refer to
Tables 4-12 and
4-13 and
perform continuity checks.
TO
FROM
S5-2
P4-A
S6-1
P4-B
P2-C
P4-C
K7-C2
P4-C
K7B2
P4-E
S2-1
P4-F
P4-G
S2-2
L2-1
P4-H
L12
P4-I
P8-C
P4-J
P8-D
P4-K
P8-E
P4-I
L11
P4-M
P8-H
P4-N