TM 9-4120-388-14
4-18. AIR CONDITIONER (FABRIC) COVER - Continued
Removal
a.
(1) Roll cover down and secure snap fasteners.
(2) Remove four screws, eight flat washers, and four packing with retainers from the top.
(3) Remove ten screws and flat washers from the sides.
(4) Carefully remove the fabric cover.
b . Cleaning
(1) Wipe dean with rag and mild detergent solution.
(2) Thoroughly rinse with fresh water and dry.
c.
Lubrication
(1) Snaps may be lubricated with silicone type lubricant or a wax stick.
(2) Turnbutton fasteners may be lubricated with silicone type lubricant or light oil (item 7, Appendix E).
Inspection/Repair
d.
(1) Inspect for rips, cuts, tears, or punctures in the fabric.
(2) Inspect for damaged, loose, or missing eyelets and snap fasteners.
(3) For repair, notify your supervisor.
e.
Installation
(1) Align eyelets to casing mounting holes.
(2) Secure top of fabric cover with four screws, eight flat washers, and four packing with retainers.
(3) Secure sides with ten screws and flat washers.
(4) If the air conditioner is to be returned to normal operation, open the snap fasteners, roll up the back flap,
and secure it with the stowing straps and turnbutton fasteners.
NOTE
If the air conditioner installation requires remend of cover, reinstall the mounting screws,
washers, and packing with retainers. This will protect the threads in the casing and prevent
air leak.