TM9-4120-400-14
CONDENSER FAN, MOTOR, AND HOUSING. - continued
4-44.
13. Tighten cap screws (1) in motor mounting plate (3) and check that fan (6) rotates freely and has adequate
clearance to fan inlet ring (27).
14. Connect P4, P5, P6, P8, and P9 connector plugs.
15. Secure cable and harnesses with new plastic tie down straps or lacing cord.
NOTE
FOLLOW-ON MAINTENANCE:
b. Cleaning
a. Inspection
This task covers:
INITIAL SETUP
Equipment
Condition
Tools
Refrigeration Unit Service Tool Kit
Scrub Brush
General Safety Instructions
Compressed air used for cleaning purposes will not
exceed 30 psi (2.1 kg/cm2).
Do not use steam to clean coil.
4-110