TM9-4120-400-14
]
[
5-25.
REPLACEMENT
1. Remove top nut (1), data plate (2), and coil (3) from tube and plunger assembly (4). Carefully lay coil (3) aside.
2. Remove two screws (5), tube and plunger assembly (4) , O-ring (6), and diaphragm (7) from valve body (8).
3. Remove two screws (9) and Iockwashers (10) that attach valve body (8) to bracket (11).
4. Debraze joints and remove valve body (8). (See para 5-12.)
5. Remove two screws (5), tube and plunger assembly (4) , O-ring (6), and diaphragm (7) from new valve
body (8).
6. Install flush bushings (12) in valve body (8).
8. Secure valve body (8) to bracket (11) with two screws (9) and Iockwashers (10).
9. Install O-ring (6), diaphragm (7), and tube and plunger assembly (4). Secure to valve body (8) with two
screws (5).
10. Install coil (3) and data plate (2), with attaching nut (1) on tube and plunger assembly (4).
NOTE
FOLLOW-ON MAINTENANCE:
5-61