TM9-4120-400-14
HIGH PRESSURE SWITCH S4. - continued
5-28.
Figure 5-24. High Pressure Switch S4
REPLACEMENT
1.
2.
3. Tag and disconnect wire leads from high pressure switch (1).
4,
Disconnect flare nut (2) at end of capillary line from switch (1).
5.
Remove two screws (3) and lock washers (4) from switch (1).
6.
Remove screw (5), lock washer (6), and clamp (7) from capillary line (8).
7.
Carefully remove capillary line (8) through grommet (9) and remove switch (1).
8.
Insert capillary line (8) through grommet (9) hole in bulkhead.
9.
10. Connect flare nut (2).