TM 9-4120-407-14
Table 3-2. Unit Preventive Maintenance Checks and Services for Model F36T-MPI - Cont
Location
Not Fully Mission Capable
Item To
Procedures
Item
Interval
if:
Check/Service
No
Mist Eliminator -
(2) Immerse the mist eliminator
Quarterly
in the wash solution and
Cont
agitate by moving it up and
down. If necessary, carefully
use a scrub brush
remove any caked on dirt or
deposits.
(3) Empty the container or sink
and fill with enough clean
water to completely cover
the mist eliminator.
Immerse the mist eliminator
in the water and agitate by
moving it up and down.
Repeat as necessary until all
detergent residue has been
removed.
(4) Shake excess water from
mist eliminator and let stand
until it is thoroughly dry.
Check condensate trap (1) and
Condensate Traps
Condensate trap damaged,
Quarterly
tubes (2) for any visible
or parts missing.
damage such as cut or split
plastic tubing, crushed or
cracked metal drain tube,
damaged or missing
condensate trap spring or
ball, and cracked or broken
barbed tee fitting. If any
components are damaged or
missing, replace them per
3-20