TM 9-4120-408-14
5-7. CONDENSER VANE AXIAL FAN MAINTENANCE. (Continued)
d. Install.
NOTE
Steps 1 and 2 apply to both condenser vane axial fans.
(1) Position condenser vane axial fan (12) on condenser top panel (13) and secure with seven screws (11), flat
washers (10), new lock washers (9), and nuts (8).
(2) Install wiring harness (6) in cable clamp (4) and secure with screw (5), flat washer (3), new lock washer (2),
and nut (1).
WARNING
Two personnel are required to lift top panel.
Failure to obey this warning may result in
personal injury.
(4) Install condenser top panel (13) into condenser housing (14).
(5) Refer to paragraph 4-15 and install upper EMI/RFI ventilation panel and protective grille.
(6) Refer to wiring diagram H-2 or tags and connect condenser vane axial fan electrical leads.
Secure
condenser vane axial fan wiring harnesses with new wire ties.
(7) Follow on maintenance: (a) Refer to paragraph 4-15 and install upper condenser protective grille and
EMI/RFI ventilation panel.
(b)
(c)
Refer to applicable system technical manual and install condenser assembly.
(d)
Refer to applicable system technical manual and connect power.
5-14