TM 9-4120-408-14
Figure F-9. Wiring Harness A104P3.
PROCEDURES:
b. Remove and discard cable clamp adapter (Figure F-9, 5), insulation sleeving
(6), and insulation sleeving (7) from connector (1) and wiring.
c. Remove faulty wire from wiring harness.
e. Refer to tables F-14 and F-15 to assemble wire. Mark wire with from to termination designation and double
headed arrow on each end of wire assembly.
f. Install wire in connector (1).
g. Install new cable clamp adapter (5), insulation sleeving (6), and insulation sleeving (7), as shown in Figure F-3,
and heat shrink to a firm fit.
h. Install tiedown straps at 3.00 inch maximum intervals and at each breakout.
F-17