WARNING
Capacitors can store electrical power for extended periods of time after being
disconnected from power supply. A bleed resistor is connected across the
capacitor terminals to discharge this power more quickly. Do not touch capacitor
terminals for the first five minutes after the power has been disconnected.
(5) Carefully pull cap (9) back to expose capacitor (10) terminals then tag and disconnect wire leads and
remove capacitor.
Figure 4-27. Capacitors (C7 thru C9).
(1) Connect wire leads to capacitor (10) per tags and wiring diagram figure 4-14. Remove tags then carefully
place cap (9) over terminals.
(2) Place capacitor (10) in position with bracket (8) over it on mounting studs. Secure bracket with four flat
washers (7), new lock washers (6), and nuts (5).
(3) Close power box assembly cover (4) and turn three latches (3) to secure.
4-73