TM 9-4520-260-13
4-18.
IGNITER
This task covers:
a. Removal
c. Cleaning
e. Installation
b. Testing
d. Inspection
f. Testing
INITIAL SETUP
General Safety Instructions
Tools
Tool Kit, Service Refrigeration Unit
Material/Parts
The ignition system of this heater contains dangerous
Dry cleaning solvent
voltages which can cause severe electrical shock.
Be
sure to disconnect power before any maintenance actions.
Rags
Equipment Condition
Power disconnected and fuel supply turned off.
Clean parts in a well-ventilated area. Avoid inhalation of
solvent fumes and prolonged exposure of skin to cleaning
solvent. Wash exposed skin thoroughly. Dry cleaning
solvent is potentially dangerous to personnel. Do not use
near open flame or excessive heat. Flash point is 140
F
(60 ).
C
1.
Disconnect ignition cable (1) from igniter (2).
2.
Unscrew igniter (2) and gasket (3) from burner head (4).
4-30