TM 9-4910-387-14-1
3-2. TROUBLESHOOTING INFORMATION (cont)
TROUBLESHOOTING (cont)
MALFUNCTION
LOCATION
TEST OR INSPECTION
CORRECTIVE ACTION
LH CONTROL EQUIPMENT ASSEMBLY (cont)
8. AUXILIARY MOTOR FAILS TO START.
Step 1. Check to see if main power source is on.
Turn main power source on.
Step 2. Check to see if AUXILIARY MOTOR switch is OFF.
a. Turn AUXILIARY MOTOR switch ON.
b. If the above procedures do not correct fault, notify general support
maintenance.
3-16