TM 9-4910-387-14-1
INSTRUMENT PANEL ASSEMBLY
9. FUEL PRESSURE GAGE (1) DOES NOT INDICATE.
Step 1. Check to see if AUXILIARY MOTOR switch (2) is in OFF position.
Turn AUXILIARY MOTOR switch to ON.
Step 2. Remove RH panel assembly and check fuel level sight gage (3).
a. If fuel tank assembly is low or empty, remove cap (4) and fill with
fuel (item 13, app C).
b. If the above procedures do not correct fault, notify organizational
maintenance.
3-17