TM 9-4910-387-14-2
NOTE
To ensure thermal heater is not shorted, set leads on
contacts and pull out on RESET. On later model
testers, remove heater element and push down on
heater switch.
3 Remove both leads. Connect one multimeter lead to
the thermal heater contact (10). Connect the other lead
to the thermal heater contact (11).
NOTE
Some testers have only two thermal heaters instead
of three. For testers with two thermal heaters, omit
steps 4 and 5.
4 Remove both leads. Connect one multimeter lead to
the thermal heater contact (12) and the other lead to the
thermal heater contact (13).
5 Remove both leads. Connect one multimeter lead to
the thermal heater contact (14) and connect the other
lead in sequence to starter contact C8 (15) and to starter
contact (16) on reverse side of starter.
6 Remove both leads. Connect one multimeter
lead to starter contact C9 (17). Connect other
lead in sequence to terminal B6 (18) and to the
FORWARD-OFF-REVERSE switch contact (19).
7 Remove both leads. Connect one multimeter
lead to the FORWARDOFF-REVERSE switch
contact (20). Connect other lead in sequence to
terminal B4 (21) and to STOP switch contact (22).
6-29