TM 9-4910-387-14-2
NOTE
3 Check for continuity. If
continuity is
not present, replace the open
Each wire that is tested for continuity should also be tested for a
short to the tester frame. This is done by placing one multimeter
lead on the wire terminal and the other lead to the tester frame.
4 If auxiliary motor fails to start, proceed to step C.
Check for continuity. If continuity exists, the wire is shorted to
ground and must be replaced. This only applies to wires not
connected to ground.
C.
WIRES MAY BE OPEN.
NOTE
Wires coming from auxiliary motor are tagged for identification.
Remove tape and wire nuts from wire ends to make continuity
checks. After making checks, replace wire nuts and apply tape
(4)
1 Connect one multimeter lead to L2
contact (1) on
the
forward side of starter. Connect the other lead in sequence
to terminals A7 (2) and B7 (3), and to contact (4) on
AUXILIARY MOTOR switch.
6-33