TM 9-4910-387-14-2
6-5. RH CONTROL EQUIPMENT ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont)l
REASSEMBLY OF RH MOUNTING BOARD ASSEMBLY (cont)
48 WIRE. Solder bare end to
stepping relay reset coil contact (56) and
position other end with terminal lug on terminal D10.
49 WIRE. Solder bare end to
latching relay contact (57) and position
other end with terminal lug on terminal D10.
50 SCREW (58). Install through two terminal lugs into terminal D10.
51 WIRE. Solder bare end to
latching relay contact (59) and position
other end with terminal lug on terminal D11.
52 WIRE. Solder bare end to
holding relay contact (60) and position
other end with terminal lug on terminal D11.
53 SCREW (61). Install through two terminal lugs into terminal D11.
6-208