TM 9-4910-387-14-2
6-6. LH CONTROL EQUIPMENT ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont)
REASSEMBLY OF LH MOUNTING BOARD ASSEMBLY (cont)
36 WIRE. Position one end with terminal lug to
forward tachometer
reversing relay contact (46) and position other end with terminal lug
on terminal B5.
37 SCREW (47). Install.
38 WIRE. Position one end with terminal lug on terminal B5 and
secure other end on starter contact (48) with screw (49).
39 SCREW (50). Install through two terminal lugs into terminal B5.
40 WIRE. Position one end with terminal lug to
reverse tachometer
reversing relay contact (51) and position other end with terminal lug
on terminal B6.
41 SCREW (52). Install.
42 WIRE. Position one end with terminal lug on terminal B6 and
secure other end on starter contact (53) with screw (54).
43 SCREW (55). Install through two terminal lugs into terminal B6.
6-236