TM 9-4935-481-14-1
C3
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
460
CIP
COUNTER INHIBIT(SEC) dial to 16.90.
SEQUENCE
Reading
461
CIP
RUN/HOLD/OFF switch to RUN.
462
PPE
Set SEQUENCE switch to the position indicated, momentarily actuate TEST START switch, then
470
AUTO 13
332.95 to 333.05 msec
momentarily depress the RESET pushbutton and observe the Counter reading for each switch
Replace card A11. Check A11 pins 120, 11, 12 and 89.
setting.
471
AUTO,8
85.55 to 85.65 msec
SEQUENCE
Reading
(63)
463
AUTO 2
307.95 to 308.05 msec
472
AUTO 9
171.25 to 171.35 msec
(58)
(64)
464
AUTO 3
426.95 to 427.05 msec
473
AUTO 14
171.25 to 171.35 msec
(59)
Replace card A11. Check A11 pins 129, 4 and 3.
465
AUTO 4
301.95 to 302.05 msec
474
AUTO 15
171.25 to 171.35 msec
(60)
Replace card A11. Check A11 pins 129, 4 and 3.
466
AUTO
434.95 to 435.05 msec
475
AUTO 10
83.95 to 84.05 msec
(61)
(65)
467
AUTO 6
332.95 to 333.05 msec
476
AUTO 11
174.65 to 174.75 msec
(62)
(66)
468
AUTO 7
332.95 to 333.05 msec
Replace card A11. Check A11 pins 120, 11, 12 and 89
477
MCP
Adjust COMPARATOR THRESHOLD B control to +2.500 0.001 Vdc.
469
AUTO 12
332.95 to 333.05 msec
DMM
Replace card A11. Check A11 pins 120, 11, 12 and 89.
478
PPE
SEQUENCE switch to AUTO 8.
479
PPE
FUNCTION TEST switch to PULSE READ.
480
ITP
INTERNAL TEST switch to 9.
3-93