524
PPE
Momentarily actuate TEST START switch.
SEQUENCE
Reading
525
PPE
Set SEQUENCE switch to the positions indicated and observe the DMM reading for each switch setting.
514
AUTO 15
243.95 to 244.05 msec
SEQUENCE
Reading
Replace card A11. Check A11 pins 120, 68, 69, 67 and 3.
526
AUTO 2
+8.100 to +8.180 Vdc
(71
515
CIP
COUNTER INHIBIT(SEC) dial to 18.41.
527
AUTO 3
+9.950 to +10.05 Vdc
516
PPE
Set SEQUENCE switch to the position indicated, actuate TEST START Switch and observe the Counter
(72)
CT
reading for each switch setting, after INHIB lamp illuminates.
528
AUTO 4
+9.950 to +10.05 Vdc
PPE
(70)
529
AUTO 5
+9.950 to +10.05 Vdc
SEQUENCE
Reading
(71)
517
AUTO 8
85.55 to 85.65 msec
530
AUTO 6
+7.620 to +7.700 Vdc
(70)
518
AUTO 9
171.25 to 171.35 msec
531
AUTO 7
+9.950 to +10.05 Vdc
519
AUTO 11
174.65 to 174.75 msec
(70)
520
AUTO 14
171.25 to 171.35 msec
532
AUTO 8
+8.100 to +8.180 Vdc
521
AUTO 15
171.25 to 171.35 msec
Replace card A12. Check A12 pins 89, 91 and 92.
Corrective action for steps 517 through 521 is:
Replace
card A11.
533
AUTO 9
+9.950 to +10.05 Vdc
Check A11 pins 120 and 1.
(70)
534
AUTO 10
+8.100 to +8.180 Vdc
Pulse Amplitude
Replace Card A12. Check A12 pins 89, 91 and 92.
522
PPE
FUNCTION TEST switch to PULSE READ.
523
MCP
SELECTOR B switch to E9.
3-95