TM 9-4935-481-14-1
C3
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
481
MCP
SELECTOR A switch to I-24.
503
MCP
SELECTOR B switch to F4.
482
MCP
SELECTOR B switch to H13.
504
CIP
COUNTER INHIBIT(SEC) dial to 17.01.
483
CT
FUNCTION switch to TIME A B.
505
PPE
FUNCTION TEST switch to INT-CLK.
484
CT
B INPUT switch to pos.
506
ITP
INTERNAL TEST switch to 7.
485
CT
Adjust DISPLAY control fully cw (to HOLD).
507
CT
FUNCTION switch to PERIOD A.
486
PPE
Momentarily actuate TEST START switch.
508
CT
Adjust DISPLAY control to mid-range.
487
CIP
Observe INHIB lamp illuminated after = 17 seconds.
NOTE
In steps 510 through 514, allow the INHIB lamp to illuminate prior to
488
CIP
RUN/HOLD/OFF switch to HOLD.
observing the reading.
489
CIP
COUNTER INHIBIT(SEC) dial to 17.01.
509
PPE
Set SEQUENCE switch to the position indicated, actuate TEST START switch and observe the Counter
490
CT
Momentarily depress RESET pushbutton.
reading for each switch setting after INHIB lamp illuminates.
491
CIP
RUN/HOLD/OFF switch to RUN.
SEQUENCE
Reading
492
CT
Observe a reading of 9.00 to 11.00 msec.
510
AUTO 8
357.95 to 358.05 msec
(67)
Replace card A11. Check 11 pins 120, 62, 63, 61 and 6.
493
CIP
RUN/HOLD/OFF switch to HOLD.
511
AUTO 9
248.95 to 249.05 msec
494
CIP
COUNTER INHIBIT (SEC) dial to 18.39.
(69)
495
CIP
RUN/HOLD/OFF switch to RUN.
512
AUTO 11
248.95 to 249.05 msec
496
CT
A INPUT switch to neg.
Replace card A11. Check A11 pins 120 and 2.
497
CIP
Observe INHIB lamp illuminated.
513
AUTO 14
364.95 to 365.05 msec
498
CIP
RUN/HOLD/OFF switch to HOLD.
(70)
499
CIP
COUNTER INHIBIT(SEC) dial to 18.41.
500
CT
Momentarily depress RESET pushbutton.
501
CIP
RUN/HOLD/OFF switch to RUN.
502
CT
Observe a reading of 9.00 to 11.00 msec.
(68)
3-94