TM9-4935-481-14-1
Table 3-11. DMS-D
Performance Test-Continued
Table 3-11. DMS-D
Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1925
TP
Momentarily actuate TEST START switch.
1947
MCP
Connect a 10215396 cable to J15 and the white probe to pin "GG" of
1926
CIP
Observe INHIB lamp illuminated before continuing.
the adapter at J5.
1927
TP
Observe GO and NO GO lamps illuminated.
1948
MCP
Connect a 11154430 jumper cable from pin "GG" to pin "S" of the
1928
CIP
COUNTER INHIBIT(SEC) dial to 07.51.
adapter at J5.
1929
TPS
Adjust AMPTD(VOLTS) dial to -0.1283 0.0005 Vdc.
1949
TPS
TRIGGER OUTPUT switch to MNL.
DMM
1950
PPE
SEQUENCE switch to OFF.
1930
TP
Momentarily actuate TEST START switch.
1951
PPE
Momentarily actuate TEST START switch.
1931
CIP
Observe INHIB lamp illuminated before continuing.
1952
TPS
Momentarily actuate TRIGGER switch.
1932
TP
Observe GO and NO GO lamps illuminated.
1953
MCP
Adjust COMPARATOR THRESHOLD B control to -4.000 0.002 Vdc.
1933
CIP
COUNTER INHIBIT(SEC) dial to 09.51.
DMM
1934
TPS
Adjust AMPTD(VOLTS) dial to -0.0995 0.0005 Vdc.
1954
TPS
Adjust AMPTD(VOLTS) dial fully cw.
DMM
1955
TP
Momentarily actuate TEST START switch.
1935
TP
Momentarily actuate TEST START switch.
1956
CIP
RUN/HOLD/OFF switch to OFF.
1936
CIP
Observe INHIB lamp illuminated before continuing.
1957
TP
Observe GO and NO GO lamps extinguished.
1937
TP
Observe GO and NO GO lamps illuminated.
Replace card A17. Check A17 pins
1938
MCP
Disconnect the 1W20 cable, BNC tee and 10215396 cable from J12
118, 104, 3, 56, 2, 28, 29, 4,
and the adapter at J5.
57 and 55.
1939
MCP
SELECTOR A switch to F1.
1958
TPS
Adjust AMPTD(VOLTS) dial slowly ccw until the GO lamp just
1940
MCP
Adjust COMPARATOR THRESHOLD B control to -4.000 0.002 Vdc.
TP
DMM
illuminates.
1941
VWS
Adjust AMPTD(VOLTS) control fully cw.
1959
MCP
SELECTOR A switch to I-24.
1942
VWS
+DC/PULSE/-DC switch to +DC.
1960
DMM
Observe a reading of +1.045 to 1.055 Vdc.
1943
MCP
SELECTOR C switch to D24.
Replace card A17. Check A17 pins
1944
TPS
Adjust AMPTD(VOLTS) dial to 1.10.
118, 104, 3, 56, 2, 28, 29, 4,
1945
TP
MODE switch to UP ERROR.
57 and 55.
1946
MCP
Connect 1W20-P1 to J12 and 1W20-P2 to J13.
1961
MCP
SELECTOR A switch to F1.
3-142