TM9-4935-481-14-1
Table 3-11. DMS-D
Performance Test-Continued
Table 3-11. DMS-D
Performance Test-Continued
STEP
UNIT
PROCEDURE CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1805
MCP
Adjust COMPARATOR THRESHOLD B control to -1.012 0.001 Vdc.
1826
TPS
Adjust AMPTD(VOLTS) dial to -0.4850 0.0002 Vdc.
DMM
DMM
1806
TP
Momentarily actuate TEST START switch.
1827
TP
Momentarily actuate TEST START switch.
1807
CIP
Observe INHIB lamp illuminated before continuing.
1828
CIP
Observe INHIB lamp illuminated before continuing.
1808
TP
Observe GO and NO GO lamps illuminated.
1829
TP
Observe GO and NO GO lamps illuminated.
1809
MCP
Adjust COMPARATOR THRESHOLD B control to -1.032 0.001 Vdc.
1830
TPS
Adjust AMPTD(VOLTS) dial to -0.4932 0.0002 Vdc.
DMM
DMM
1810
TP
Momentarily actuate TEST START switch.
1831
TP
Momentarily actuate TEST START switch.
1811
CIP
Observe INHIB lamp illuminated before continuing.
1832
CIP
Observe INHIB lamp illuminated before continuing.
1812
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1833
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1813
MCP
Adjust COMPARATOR THRESHOLD B control to -0.9720 0.0010 Vdc.
1834
TPS
Adjust AMPTD(VOLTS) dial to -0.3370 0.0002 Vdc.
DMM
DMM
1814
TP
Momentarily actuate TEST START switch.
1835
TP
Momentarily actuate TEST START switch.
1815
CIP
Observe INHIB lamp illuminated before continuing.
1836
CIP
Observe INHIB lamp illuminated before continuing.
1816
TP
Observe GO and NO GO lamps illuminated.
1837
TP
Observe GO and NO GO lamps illuminated.
1817
MCP
Adjust COMPARATOR THRESHOLD B control to -0.9520 0.0010 Vdc.
1838
TPS
Adjust AMPTD(VOLTS) dial to -0.3288 0.0002 Vdc.
DMM
DMM
1818
TP
Momentarily actuate TEST START switch.
1839
TP
Momentarily actuate TEST START switch.
1819
CIP
Observe INHIB lamp illuminated before continuing.
1840
CIP
Observe INHIB lamp illuminated before continuing.
1820
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1841
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1821
CIP
COUNTER INHIBIT(SEC) dial to 10.11.
1842
MCP
Disconnect both 1W20 cables from J12, J13, J17 and the BNC tee.
1822
MCP
DMM INPUT switch to DMM INPUT.
1843
MCP
Disconnect the 10215396 cable from the BNC tee and pin "GG" of
1823
MCP
SELECTOR A switch to D24.
the adapter at J5.
1824
VWS
Adjust AMPTD(VOLTS) control to +0.4110 0.0020 Vdc.
1844
MCP
Disconnect the BNC tee from J15,
DMM
1845
MCP
Connect 1W20-P1 to J12 and 1W20-P2 to a BNC tee.
1825
MCP
DMM INPUT switch to SEL A.
3-139