C4
TM9-4935-481-14-1
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1751
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1731
TP
Momentarily actuate TEST START switch.
(172)
1732
CIP
Observe INHIB lamp illuminated before continuing.
1752
VWS
Adjust AMPTD(VOLTS) control to +0.972 0.0010 Vdc.
0
1733
TP
Observe GO lamp illuminated and NO GO lamp extinguished.
DMM
(171)
1753
TP
Momentarily actuate TEST START switch.
1734
VWS
Adjust AMPTD(VOLTS) control to +6.96 0.0010 Vdc.
0
1754
CIP
Observe INHIB lamp illuminated before continuing.
DMM
1755
TP
Observe GO and NO GO lamps illuminated.
1735
TP
Momentarily actuate TEST START switch.
(172)
1736
CIP
Observe INHIB lamp illuminated before continuing.
1756
VWS
Adjust AMPTD(VOLTS) control to +0.952 0.0010 Vdc.
0
1737
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
DMM
(171)
1757
TP
Momentarily actuate TEST START switch.
1738
CIP
COUNTER INHIBIT(SEC) dal to 02.21.
i
1758
CIP
Observe INHIB lamp illuminated before continuing.
1739
MCP
DMM INPUT switch to SEL A.
1759
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1740
Delete.
(172)
1741
MCP
Adjust COMPARATOR THRESHOLD B control to -0.9920 0.0020 Vdc.
1760
CIP
COUNTER INHIBIT(SEC) dial to 10.11.
DMM
1761
MCP
DMM INPUT switch to SEL A.
1742
MCP
DMM INPUT switch to DMM INPUT.
1762
MCP
Adjust COMPARATOR THRESHOLD B control to -0.4110 0.0020 Vdc.
1743
VWS
Adjust AMPTD(VOLTS) control to +1.01 0.0010 Vdc.
2
DMM
DMM
1763
VWS
+DC/PULSE/-DC switch to +DC.
1744
TP
Momentarily actuate TEST START switch.
1764
MCP
DMM INPUT switch to DMM INPUT.
1745
CIP
Observe INHIB lamp illuminated before continuing.
1765
VWS
Adjust AMPTD(VOLTS) control to +0.485 0.0002 Vdc.
0
1746
TP
Observe GO and NO GO lamps illuminated.
DMM
(172)
1766
TP
Momentarily actuate TEST START switch.
1747
Delete.
1767
CIP
Observe INHIB lamp illuminated before continuing.
1748
VWJS
Adjust AMPTD(VOLTS) control to +1.03 0.0010 Vdc.
2
1768
TP
Observe GO and NO GO lamps illuminated.
DMM
1749
TP
Momentarily actuae TEST START switch.
t
1750
CIP
Observe INHIB lamp illuminated before continuing.
3-137