TM9-4935-481-14-1
Table 3-11. DMS-D
Performance Test-Continued
Table 3-11. DMS-D
Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
1883
TPS
Adjust AMPTD(VOLTS) dial to -0.1283 0.0005 Vdc.
1904
MCP
Adjust COMPARATOR THRESHOLD B control to -2.325 0.001 Vdc.
DMM
1884
TP
Momentarily actuate TEST START switch.
1905
TP
Momentarily actuate TEST START switch.
1885
CIP
Observe INHIB lamp illuminated before continuing.
1906
CIP
Observe INHIB lamp illuminated before continuing.
1886
TP
Observe GO and NO GO lamps illuminated.
1907
TP
Observe GO lamp illuminated and NO GO lamp extinguished.
1887
CIP
COUNTER INHIBIT(SEC) dial to 09.51.
1908
MCP
Adjust COMPARATOR THRESHOLD B control to -2.275 0.001 Vdc.
1888
TPS
Adjust AMPTD(VOLTS) dial to -0.0995 0.0005 Vdc.
DMM
DMM
1909
TP
Momentarily actuate TEST START switch.
1889
TP
Momentarily actuate TEST START switch,
1910
CIP
Observe INHIB lamp illuminated before continuing.
1890
CIP
Observe INHIB lamp illuminated before continuing.
1911
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1891
TP
Observe GO and NO GO lamps illuminated.
1912
CIP
COUNTER INHIBIT(SEC) dial to 01.51.
1892
TP
MODE switch to DIVIDE 2.
1913
MCP
Adjust COMPARATOR THRESHOLD B control to -0.5400 0.0010 Vdc.
1893
MCP
SELECTOR A switch to Fl.
DMM
1894
CIP
COUNTER INHIBIT(SEC) dial to 00.21.
1914
TP
Momentarily actuate TEST START switch.
1895
MCP
Remove the white probe from pin "M" of the adapter at J5 and
1915
CIP
Observe INHIB lamp light illuminated before continuing.
connect it to pin "K".
1916
TP
Observe GO and NO GO lamps illuminated.
1896
MCP
Adjust COMPARATOR THRESHOLD B control to -2.675 0.001 Vdc.
1917
CIP
COUNTER INHIBIT(SEC) dial to 03.51.
1897
TP
Momentarily actuate TEST START switch.
1918
MCP
SELECTOR A switch to D24.
1898
CIP
Observe INHIB lamp illuminated before continuing.
1919
TPS
Adjust AMPTD(VOLTS) dial to -0.2650 0.0005 Vdc.
1899
TP
Observe GO lamp illuminated and NO GO lamp extinguished.
DMM
1900
MCP
Adjust COMPARATOR THRESHOLD B control to -2.725 0.001 Vdc.
1920
TP
Momentarily actuate TEST START switch.
DMM
1921
CIP
Observe INHIB lamp illuminated before continuing.
1901
TP
Momentarily actuate TEST START switch.
1922
TP
Observe GO and NO GO lamps illuminated.
1902
CIP
Observe INHIB lamp illuminated before continuing.
1923
CIP
COUNTER INHIBIT(SEC) dial to 05,51.
1903
TP
Observe GO lamp extinguished and NO GO lamp illuminated.
1924
TPS
Adjust AMPTD(VOLTS) dial to -0.1813 0.0005 Vdc.
DMM
3-141