TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
x4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER
(PLGR) (CONT)
Step (2) Check to see if Precision Lightweight Global Positioning System Receiver (PLGR) has power.
If PLGR does not have power, notify Unit Maintenance.
(a)
Position electrical distribution block cover on power distribution shelf.
(b)
Tighten wing screw on electrical distribution block cover.
(c)
Install wing screw in power distribution shelf.
X5. NO POWER TO
DRIVER VISUAL ENHANCEMENT (DVE)
WARNING
Remove rings, brackelets, wristwatches, neck chains, and any other jewelry before
working around vehicle. Jewelry may catch on equipment or may short across an
electrical circuit. Failure to comply may result in serious injury or death to personnel.
Step 1. Check to see if circuit breaker (CB6) is tripped.
(a)
Remove wing screw from power distribution shelf.
(b)
Loosen wing screw on electrical distribution block cover.
(c)
Remove electrical distribution block cover from electrical distribution shelf.
Change 2