TM 9-4120-370-14
TO 35E9-229-1
4-69. CONDENSER COIL CLEANING -
Continued.
Compressed air used for cleaning purposes will not exceed 30 psi (2.1 kg/cm2) .Do
not direct compressed air against the skin. Use goggles or full face shield.
CAUTION
Do not use steam to clean coil.
b. Cleaning. Clean coil with a soft brittle brush, vacuum cleaner and brush attachment, or use compressed air
at 30 psi or less from the inside of the unit to blow the dirt out. Take care to avoid fin damage. When using com-
pressed air, wear safety glasses or goggles. Dirt can be blown into your eyes.
Repair/Replacement. Should a leak or major damage be evident, refer to direct support maintenance.
c.
Follow-on procedures:
2. Install condenser discharge air deflector door on F36T-2SA and F36T4-2SB (See Para
This part is supplied only when specified on air conditioner ordering information
NOTE
This paragraph is applicable only on units that have been specially equipped with a
sound attenuator. When sound attenuator is installed. conditioned air intake and outlet
grilles must be removed.