TM 55-1925-284-14&P
OPERATOR MAINTENANCE
MARINE SANITATION DEVICE FOR
INLAND AND COASTAL LARGE TUG (LT)
MARINE SANITATION DEVICE, SERVICE
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, General Mechanic's (Item 1, Table 2,
Two Watercraft Engineers, 88L
Test Kit, Sanitizer (Item 6, Table 2,
References:
FM 55-502
Suitable Sample Bottle
TM 55-1925-273-10
Suitable Drain Pan
Materials/Parts:
Gloves, Chemical and Oil Protective (Item 1,
Goggles, Industrial (Item 2, Table 3, WP 0038)
Equipment Conditions:
Silicone Compound (Item 6, Table 1
All ventilation fans operating normally (TM 55-1925-
273-10)
RESIDUAL CHLORINE TEST
1. Place a suitable drain pan under the WET WELL SAMPLE valve MSD-11(figure 1, item 1).
WARNING
Sewage is a common mode of transmission for parasitic organisms that may
have the capability of causing communicable diseases. After coming in contact
with sewage or contaminated equipment, be sure to clean yourself with a disin-
fectant soap. Avoid sewage contact with skin abrasions, punctures, cuts, and
other open wounds. Wipe up and clean any spills and/or contaminated equip-
ment using a disinfectant soap. Failure to comply can lead to serious illness.
2. OPEN and CLOSE the WET WELL SAMPLE valve MSD-11 (figure 1, item 1) to remove any contaminants
from the piping.
0014 00-1