INTERVEHICULAR CABLE RECEPTACLE - CONTINUED
INITIAL SETUP
Tools
Handle, reversible, 3/8-inch square
drive
Socket, 7/16- by 3/8-inch square
drive
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
Using socket and handle, remove.
Four capscrews (3)
1. Reach tube (1) to
receptacle
and four lock-
cover (2)
washers (4)
Remove.
Receptacle cover (2)
2. Receptacle (5)
a. Remove.
3. Reach tube (1)
Receptacle (5)
b. Guide wire harness connectors through
hole.
NOTE
Prior to disconnecting mated connectors, note numbers on identification bands. If
numbers are not legible or identification bands are missing, tag wire with proper
identification numbers.
Eight mated
Separate.
4. Reach tube section
wire harness (6)
connectors (7 and 8)
INSTALLATION
Reconnect to eight mated connectors (7)
Eight receptacle
5. Reach tube section
and remove identification tags.
wire harness (6)
connectors (8)
Eight mated
Guide connectors into reach tube recess.
6. Reach tube (1)
connectors (7 and 8)
Position, alining mounting holes.
Receptacle (5) and
7.
receptacle cover (2)
Four capscrews
Using socket and handle, install.
8. Receptacle (5)
(3) and four
and receptacle
Iockwashers (4)
cover (2)