TM 9-2330-356-14
attempt to inspector repair tank until it has been drained
(7) On the M970 and M970A1 only, connect the
75-inch cable to the U-bolt connection on valve operator
A.
b.
Inspection. Inspect tank for leaks, punctures, or
(8) Thread cable through cable guide on cabinet
dents.
and connect cable to hose reel cabinet door shut-off.
c.
Repair. Straighten dented metal with rubber
mallet or a block of wood and heavy hammer. Repair
cracks by welding (TM 9-237).
(10) Cut excess cable 1-inches from all U-bolt
connect ions.
M970)
WARNING
a.
Removal (Pig. 6-11).
Do not use an acetylene torch to fuse cable
ends unless tank has been cleaned and
purged. Failure to follow this warning may
result in serious Injury or death to personnel.
(2) Check pulley in pump intermediate housing
to ensure that the two bolts attaching flex plates to pulley
(11) Unless the tank has been cleaned and purged
are accessible for removal. If bolts cannot be removed,
for other maintenance, crimp the cable ends to keep them
from unraveling. DO NOT fuse them unless tank has been
5/8-inch socket on a long extension, and insert it through
purged.
the hole and onto fan bolt. With a socket wrench, turn
engine clockwise until bolts can be removed.
(3) Remove two bolts and four washers holding
a.
Cleaning and Purging. Observe safety precautions
flex plates to pulley.
given in the Warning Summary at front of manual. Do not
Figure 6-11. Removal of
Alternator Drive Belt (M967, M969,
and M970).