TM 9-2330-356-14
8-22. Vehicle Nozzle (M969 and M969A1)
a.
b.
(1)
Place nozzle assembly on a clean work area.
(2) Unscrew ground wire from nozzle handle.
(3) Disconnect the chain for the cap from the
nozzle.
(4) Unscrew the spout from nozzle handle and
remove the strainer.
c.
Cleaning and Inspection.
WARNING
Dry cleaning solvent P-D-680 is toxic and
flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated
area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO
NOT use near open flame or excessive heat.
The solvent's flash point is 100F-138F
(38C-59C). If you become dizzy while
using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes,
immediately wash your eyes with water and
get medical aid.
TA223050
(1) Clean the strainer, spout, and nozzle handle
with dry cleaning solvent (item 11, Appendix E) and dry
8-23. Overwing Nozzle (M970 and M970A1)
thoroughly.
a.
(2) Check spout, screen, rubber cap and chain,
and ground wire and connector for damage.
b.
(3) Replace any damaged part.
(1) Place nozzle assembly on a clean work area.
d.
(2) Unscrew ground wire from nozzle handle.
(1) Insert strainer into spout and screw spout
(3) Disconnect the chain for the cap from the
onto handle.
nozzle.
(2) Reconnect cap and chain to the nozzle.
(4) Unscrew the spout from nozzle handle and
remove the strainer.
(3) Screw ground wire into nozzle handle.
e. Installation. Install vehicle nozzle to hose
(5) Loosen thumb screw and slide protector ring
off end of spout.