TM 9-2330-357-14&P
4-25. LOWER OUTRIGGER LIMIT SWITCH MAINTENANCE (Con't).
d. ADJUSTMENT
1.
NOTE
Screw length is checked from top of ball nut to top of screw. DO NOT include rod end
nut in check.
2.
until amount of screw (9) showing from ball
nut (11) is equal to the width of the switch
adjustment tool (10).
3.
Set control panel power switch to OFF
position.
4.
Tag and disconnect two switch connectors (7) from harness connectors.
5.
Set multimeter to R x 1 (Ohms scale) and zero meter.
NOTE
Ensure that multimeter probes are connected
to switch connectors and not to harness con-
nectors.
6.
connectors (7).
7.
Loosen four screws (6).
8.
Move bracket (1) until multimeter indicates 0
(zero) ohms.
9.
Move bracket (1) until multimeter indicates
(infinite) ohms.
10.
Tighten four screws (6).
TA706454
4-39