TM 9-2330-357-14&P
4-30. WIRING HARNESS REPAIR (Con't).
e. CONNECTOR RECEPTACLE REPAIR
NOTE
Male and female inserts are replaced In the same way. This procedure covers male.
Insert replacement.
1.
Remove receptacle (21) from grommet
retaining nut (19).
2.
Remove grommet (22) from receptacle (21).
Cut insert (23) from wire (20). Discard insert.
3.
Remove grommet (22), receptacle (21), and
grommet retaining nut (19) from cable (18).
4.
Strip insulation off wire (20) equal to depth of
new insert (23).
5.
Thread cable (18) through grommet retaining
nut (19), receptacle (21), and grommet (22).
6.
Position new Insert (23) on wire (20) and
7.
Press grommet (22) into receptacle (21) until
seated
8.
Install receptacle (21) on grommet retaining
nut (19).
FOLLOW-ON TASKS:
Connect tractor truck intervehicular cable to semitrailer (para 2-10).
TA706465
4-52