TM 9-2330-381-14
WARNING
Hydraulic fluid may be under pressure. Two wrenches must be used when
disconnecting hydraulic lines or components or injury to personnel and damage to
equipment may result.
Hydraulic fluid can be absorbed through the skin. Wear long sleeves, gloves, and
goggles or face shield. If hydraulic fluid gets into eyes, flush immediately with
water and seek medical attention. If hydraulic fluid gets on skin, wash thoroughly
with soap and water. Wash hands thoroughly prior to eating or smoking.
REMOVAL
1.
2.
Using isolation valve handle extension, close all suspension isolation valves (para. 2-6).
3
Place hydraulic floor jack (1) under lower suspension arm (2) and operate floor jack until it makes firm contact
with lower suspension arm.
4-175