16.
Using two people, slide adjustment fitting (16) and spring (12) upward on guide rod (8) until top of spring is
positioned even with bottom of tube guide (27) located on underside of weldment bracket (13).
NOTE
Holes in lower end of guide rod are staggered and spaced 0.5 inch (1.27 cm) apart.
17.
With top of spring (12) positioned as described in step 16 above, aline holes in adjustment fitting (16) with hole in
rod (8), which places top of spring within 0.75 inch (1.9 cm) of underside of weldment bracket without touching.
Install capscrew (15) and locknut (14).
18.
19.
Check spring adjustment.