TM 9-2330-383-14&P
3-4.
OPERATOR TROUBLESHOOTING TABLE (CONT)
Table 3-1. Operator Troubleshooting Table - CONT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONT
1. ALL LAMPS DO NOT LIGHT - CONT.
Step 2.
Check intervehicular cable.
a.
If cable is not properly connected, reconnect cable.
b.
If cable is properly connected, proceed to step 3.
Step 3.
Check connectors for dirty or corroded pins. Check for damaged pins.
a.
If pins are dirty or corroded, clean the pins.
b.
If cables are damaged, notify unit maintenance.
2. ONE OR MORE (BUT NOT ALL) LIGHTS WILL NOT LIGHT.
Step 1.
Check for broken lead wires or loose connections.
a.
If connections are loose, tighten connections.
b.
If lead wires are broken, notify unit maintenance.
c.
If connections are not loose or broken, proceed to step 2.
Step 2.
Check light assembly for damage.
If light assembly is damaged, notify unit maintenance.
3. DIM OR FLICKERING LIGHTS.
a.
If connections are loose, tighten connections.
b.
If connector pins are dirty or corroded, clean pins.
c.
If connections are tight and clean, notify unit maintenance.
Change 1