TM 9-2350-222-10-3
TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
40. BULLDOZER MOLDBOARD DOES NOT LIFT - Continued
Step 2. Check red buttons (C) on hydraulic oil filters (D).
If red buttons (C) are up, press down. If buttons will not stay down,
notify organizational maintenance.
Step 3. Check oil level on dipstick (E) from hydraulic oil reservoir (F).
a. Add oil if necessary (LO 9-2350-222-12).
b. If problem still exists, notify organizational maintenance.
NOTE
If required to continue vehicle operation, use Emergency
Moldboard Lifting Procedure (page 2-263).
TA132878
3-48